E50C3 | Veris | Power Monitoring & Protection
Modbus RTU DIN Rail 3-Phase Electrical Power Meter w/ Data Logging; Serial communication via Modbus RTU; Standard DIN Rail, Surface Mounted, or NEMA 4 enclosure; Front-panel, Bright Backlit LCD display; A Real Energy (Watt-Hours) Pulse Output and Phase Alarms; ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S; 90-600 VAC; Data logging capability; Compatible with CTs from 5A to 32000A; User-enabled password protection; System integration via Modbus RTU
Brand:Veris
MPN:E50C3
SKU:E50C3
List Price:
$1,340.00
Today's Price:
$696.80
Log in for customized pricingproduct specifications
Connection
Terminals
Type
1 Circuit
Communication Protocol
MODBUS
CT Inputs
3
Monitored Voltage
600 VAC
Monitored Current
32,000 A
product series specifications
Supply Voltage:
UL: 90 VAC (L-N) to 600 VAC (L-L), 50/60Hz
CE: 90 VAC (L-N) to 300 VAC (L-L), 50/60Hz
Monitored Voltage: Line to Line: 90 to 600 VAC
Line to Line with potential transformer: 601 to 32000 VAC
Monitored Current: 5 to 32,000 Amps
Available CT’s: 0 to 0.333 V or 0 to 1 V
Input Signal: 2 (E50H5 only) Pulse Solid-State or mechanical contacts (current less than 1 mA) Minimum Pulse Width 20 msec
Outputs:
E50B1 Reactive energy pulse 30 VAC/DC
E50C1 RS-485 2-wire Modbus RTU Basic Data Set
E50C2/E51C2 RS-485 2-wire, Modbus RTU Full Data Set
E50C3/E51C3 RS-485 2-wire Modbus RTU Full Data Set, data logging
E50H3 RS-485 2-wire BACnet MS/TP Full Data Set, data logging
Accuracy: Real power and energy 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S)
Operating Temperature:
Meter: 22° to 158°F (-30° to 70°C)
Display: 14° to 122°F (-10° to 50°C)
Operating Humidity: < 95% RH non-condensing
Enclosure Rating: NEMA 1
Mounting: DIN Rail or 3-point screw mount
Dimensions: 2.3" x 4.2" x 3.6" (5.9 cm x 10.7 cm 9.1 cm)
Weight: 0.62 lb (0.28 Kg)
Approvals: CE, UL508, UL File #E339785, RoHs
Warranty: 5 years
product series features
- Monitors 1, 2, or 3 phase services
- Monitors services up to 600 VAC directly and 32,000 VAC with use of a potential transformer
- Accepts .333 VAC or 1V Current Transformer's (sold separately)
- DIN mounting for easy installation
- ANSI 12.20 0.5% accuracy
- BACnet, Modbus RTU or pulse output
- 90-600 VAC for application versatility
- Bright backlit LCD with easy visibility
- Pulse and phase loss alarms standard
- User-enabled password protection
- Approved for California Solar applications
more information & related documents
Series Description
The Veris E50 Series power meter provides a solution for measuring energy data with a single device. Inputs include Control Power, CT, and 3-phase voltage. The E50 supports multiple output options, including solid state relay contacts, BACnet, Modbus (with or without data logging), and pulse. The LCD screen on the faceplate allows instant output viewing. The meter is housed in a plastic enclosure suitable for installation on T35 DIN rail according to EN50022. The E50 can be mounted with any orientation over the entire ambient temperature range, either on a DIN rail or in a panel. The meter is not sensitive to CT orientation to reduce installation errors.
Kele Description
MODBUS & PULSE OUTPUT, DATA LOGGING, 90-600V
Manufacturer
Veris