UG03-0001-41 | Flowline | Level
REFLECT ULTRASONIC LEVEL TRANS 9.8' 4 SPST W/FOB
Brand:Flowline
MPN:UG03-0001-41
SKU:UG03-0001-41
product specifications
Range
30 psi
Type
Ultrasonic Level Transmitter
Display
No
Cable Length
4 ft
Sensing Type
Ultrasonic
Supply Voltage (Nominal)
24 VDC
product series specifications
Range:
UG01: 1.5" to 4.9' (3.8cm to 1.5m)
UG03: 4" to 9.8' (10.1cm to 3m)
Accuracy:
UG01: ±0.125" (3mm)
UG03: ±0.2% of range
Resolution:
UG01: 0.019" (0.5mm)
UG03: 0.039" (1mm)
Dead Band:
UG01: 1.5" (3.8cm)
UG03: 4" (10.1cm)
Beam Width: 2" (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply Voltage: 14-28 VDC
Maximum Consumption: 0.5W
Loop Resistance: 500O @ 24 VDC
Signal Output: 4-20mA, two-wire
Signal Invert: 4-20mA or 20-4mA
Signal Fail-Safe: 4mA, 20mA, 21mA, 22mA, hold last
Contact Type: (4) SPST relays
Contact Rating: 60 VA, 1A maximum
Contact Fail-Safe: Open, closed, hold last
Contact Hysteresis: Selectable
Process Temperature: -40° to 176°F, -40° to 80°C
Temperature Comp: Automatic
Ambient Temperature: -31° to 140°F, -35° to 60°C
Pressure: 30 psi (2 bar)
Enclosure Rating: Type 6P (IP68)
Enclosure Material: Polypropylene
Transducer Type: Reflective
Transducer Mat: Polyvinylidene fluoride
Cable Jacket Mat: Polyurethane
Cable Type: 9-conductor, shielded
Cable Length: 48" (1.2m)
Process Mount: -0001: 2" NPT, -0011: 2" G
Mount Gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approvals: UL 61010-1
Compliance: CE, RoHS, C CSA US
product series features
- Offered in 1.5m (4.9ft) and 3m (9.8ft) measurement ranges
- Fail-safe diagnostics with selectable relay and signal outputs
- Narrow 2 in (5cm) beam width for applications with limited space
- Corrosion resistant PVDF transducer and compact PP enclosure
- Short 1.5 in (3.8cm) dead band maximizes tank filling capacity
- Automatic temperature compensation from -40 degrees to 80 degrees C
- Four programmable relays with embedded level control logic
- 1 pump or valve with 3 alarms
- 2 pumps lead-lag with 2 alarms
- 2 pumps duplexing with 2 alarms
- 4 independent switch point alarms
more information & related documents
Series Description
The Flowline EchoPod® UG01 & UG03 Reflective Ultrasonic Multi-Function Liquid Level Transmitter Series provides continuous level measurement up to 9.8 ft (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps. Kele is the leading supplier of building automation products. When you need the right product, right now, count on Kele.
Kele Description
REFLECT ULTRASONIC LEVEL TRANS 9.8' 4 SPST W/FOB
Manufacturer
Flowline